Scan-Sense AS
HOMEPRODUCTSABOUT USQUALITYAPPLICATIONSSERVICENEWSPRESS RELEASESCONTACT
 


:: Tensile

LOAD
  Custom design
  Shear pin
  Compression
  Tensile
  Torque
  Strain Measurement
  Portable Kits
  Subsea Load
PRESSURE
CALIBRATION
DISTRIBUTORS

 
 

:: INTRANETT


 


Tensile Load Cells

Tensile Load cells are produced to fit in the standard shackles range, 12 to 400 tonnes SWL.

Our Tensile load cells are used for measuring tension at dead-end anchor. We also produce tensile load cells as portable kits for weighing and as reference tools.

 

Full Scale Tensile Load:
(FS)
Typical 1-120 tonn
Other capacities upon request
Maximum Tensile Load at 20°C: FS range x 2, below 25 tonnes
FS range x (2....1.33) above 25 t
FS range x 1.33 above 25 t
Temperature range: -20 to 60°C
Linearity:  ± 0,2 % FS
Total accuracy at ambient temperature, the accuracy demands correct bolt dimension: Typical 0,5%
TCS (Thermal Compensated Sensitivity): Typical 0,03% FS x (temp.-amb)
Output: 1-2 mV/V / 4-20mA
Supply Voltage:  Max. 15 VDC / 24 VDC
Electrical Connector: 4 wire / 2 wire
Response time:  2 msec / 13 msec
Bridge Resistance: 4 kohm
Insulation Test: 500 V AC (RMS) > GW
Sealing: IP67
Material:  Stainless Steel
 

 

SCAN-SENSE AS  -   BEKKEVEIEN 163  -   3173 VEAR NORWAY  -   PHONE: +47 - 33 36 30 00  -   FAX: +47 - 33 36 30 01